Design Of Water Distribution And WASTE WATER COLLECTION Networks For Asira Al-Shmaliya Prepared By : Bara’ Maher Milhim Islam Majed Hassoun Mohammad Khalid Sawalha Submitted to : Dr. Abdelhaleem Khader Objectives and significance of the project Study area Methodology Modeling , Analyzing and design Results and conclusions Outline Design efficient water distribution network for Asira Al-Shamaliya village. Design waste water collection network for Asira Al-Shamaliya Objectives The water network in Asira Al-Shamaliya doesn’t work efficiently or effectively, since it has high percentage of loss which reaches 35% of water supply This redesign Asira's network to minimize the loss of water and improve its’ efficiency as much as possible. The residents of Asira ash-Shamaliya dispose their sewage using cesspits. Cesspits have many environmental problems. Accordingly, we have to design a wastewater collection network for Asira Ash-Shamaliya Significance of work Study area Asira Al-Shamaliya is a Palestinian town in the Nablus Governorate, located six kilometers north of Nablus in the northern West Bank A total urban area of the village about ​​39,000 donoms Water resources : Asira doesn't has its own resource of water, so it gets its water from wadi El-bathan and Taloza wells. Methodology Data Collection Designing Data analysis Selection of the study area Giving recommendations Contour map Road network Structural plan (Houses distribution) Boundary of study area (border of village) Reservoir location Population number and the population growth rate Demand per capita Data collection Water Distribution network (Analyzing , Designing and modeling) Population forecasting Our design period is 35 years. We use this equation : Pn=P(1+r) n: Population = 7556*(1+.027)42 = 23134 persons Data analyzing 2007 2008 2009 2010 2011 2012 2013 2014 2049 7556 7760.0119999999997 7969.5323239999989 8184.7096967479984 8405.6968585601935 8632.6506737413183 8865.7322419323318 9105.1070124645048 23133.991961300497 Year population Demand forecasting Water demand for population in Asira al-Shamaliya is 4000 m3 per week and the population is 9105 person demand per capita is 4000×1000 / 7× 9105 = 63 L/c-d The person consumption is less than 120 L/c-d, so the assumption is ok. Qd = (Future population) * L/c-day * hourly factor = 23134 * 120 * 3 = 8328.237 m³/day. Data analyzing Design considerations Velocity : The minimum and maximum allowable velocities are 0.3 and 3.0 m/s Pressure :The value of the pressure on each junction should be between “20 – 100” mH2O Cost : The design (from the designs meet the first tow consideration ) , with least cost. Designing Inserting the data to WaterCAD Allocation of junctions and reservoir Drawing pipes Add contour file to determine the elevations of junctions and reservoir and length of pipes using TRex tool. Modeling Apply Thiessen polygon theory to determine the service area of each junction Adding the total demand using load builder tool. Run the model Modeling Results Pipes table Velocities : Results The problem of high velocity was solved by enlarging the pipe diameter . While decreasing the pipe diameters for those with lower velocities than 0.3m/s Results Junctions table Pressures Results In the case of high pressure ( higher than 100 mH2O ) we use PRV ( pressure reducing valve ) Wastewater Collection network (Analyzing , Designing and modeling) Population forecasting Our design period for wastewater network is 15 years. We use this equation : Pn=P(1+r) Where: Population = 7556*(1+.027)23 = 13945 persons Data analyzing 2007 2008 2009 2010 2011 2012 2013 2014 2049 7556 7760.0119999999997 7969.5323239999989 8184.7096967479984 8405.6968585601935 8632.6506737413183 8865.7322419323318 9105.1070124645048 23133.991961300497 Year population estimation of the waste water generation per capita . Wastewater generation rate is 80%. Peak factor is 4. Infiltration rate is 20% from consumed water. We calculated the waste water generation per capita as follow. WWG/capita-day = 0.8* water consumption L/c-day * (hourly factor + infiltration percent) WWG/capita-day = 0.8*120*(4+0.2) = 403.2 L/capita-day. Data analyzing Design considerations The least conduit diameter is 8 inch "203.2 mm". used conduit is a circular PVC conduit. partial flow with a percentage of 75%. Sump depth is zero. Designing Average velocity minimum velocity is 0.6 m/s maximum velocity is 3 m/s Slope minimum slope is1% . maximum slope is 15% . Cover The minimum cover should at least be 1 m. The maximum cover should not exceed 5 m. Adding needed data to sewerCad Allocation of manholes and outfalls. Drawing Conduits. Add contour file to determine the elevations of Manholes and outfall and length of Conduits using TRex tool. Exporting these data as shapefile. Using ArcHydro tool to determine the served area by each manhole. Assigning design load on each manhole. Run the model. Modeling To determine the design load on each manhole we need the following data : Served area by each manhole (determined using ArcHydro). Population density . WWG/capita-day . Manhole design load Calculation Served area for each manhole Population density= 13945/3539379 = 0.004 capita/m2 WWG/capita-day =403.2 Manhole load = Population density*Area*WWG/capita-day Results Results Velocities : Results Results Results Conduit cover Item Cost ($) Excavation 194898 Pipes 99770 Manholes 43271 Labor 59580 Re-paving 196860 Base coarse 29529 Sand 66440 Total cost 630548 Cost/1 m 64 BOQ for sewer network we recommend replacing the current water network and constructing a waste water collection network because of the great damage caused by cesspits on the environment and groundwater, In addition to seepage problems and expenses Conclusion and Recommendations Thank YOu image1.jpeg image2.png image3.png image4.png image5.png image6.jpeg image7.jpg image8.jpeg image9.jpg image10.jpg image11.jpg image12.png image13.png image14.png image15.png image16.png /docProps/thumbnail.jpeg