Culture Center Prepared by: Isra Draghmah Sara AL-Khateeb Riham Shakarnah Supervisor : Dr. Ahmad Saleh 1 Outline: Introduction Architectural Design Structural Design Mechanical Design Safety Design Environmental Design Electrical Design Quantity surveying and cost estimation Introduction : Location: -In Nablus near An-Najah Hospital, it is located to the north of Rafidya Street , and to the north- western of city center . Total Area = 13368m^2 Location of the project is in jamal abd alnaser park in nablus in yafa street , type of restaurant is fine dinning The project is important because the municapility workiing to develop the park and theres no restaurants so it will be destination for the vsitors Area =2000m^2 3 Architectural Design Architectural Design: 1-Video . 2- Site plan and Accessibility 3- The plans 4- Sections 5- Elevations . 6-Requirements for Handicapped People Architectural Design: Site plan: The main entrance of the restaurant is from Jamal Abdel Nasser Park, the secondary entrance of parking, management, and services are from Yafa Street as shown in the figure below. The site contains parking which the capacity of it about 36 car, and there are two ramps the first one for entrance, and the second one for exit 7 Ground Floor Area=3256.3m^2 The ground floor contains the reception and cashier, coat room, kitchen, dining area, mechanical and electrical rooms and storage 8 First Floor Area=3864.83m^2 Sections Elevations : Requirements for Handicapped People Ramps Special W.C Structural Design Structural Design: 1- Design codes 2- Loads 3- Sap model and checks 4- Structural elements and detailing Design Codes: ACI-318-08 for reinforced concrete design . UBC-97 for earthquake load computations . ASCE for load computations Loads: Type of loads Load (KN/m2) Live load 5KN/m2 Super imposed 3KN/m2 Exterior walls 21KN/m 19 We have many slab system : 1- one way ribbed slab (40 cm thickness ) 2- two way ribbed slab (40 cm and 50 cm thickness ) with Drop beams . 3- Shell structure ( 15 cm ) . Section in one way ribbed slab 20 Sap model: Checks for model : 1. Compatibility check: Deflection check: U from sap = 28.6mm < U max= 62mm compatibility had achieved as shown in the figure 22 2. Equilibrium check: Load Manual Sap Error Dead load 22159.26 KN 22434.11KN 1.24% Live load 13328.28KN 12985.36KN 2.57% 3. Internal Forces Check: Load Manual Sap Error For Dead load Slab 127.31 KN.m 148.206 KN.m 16.4 % Load Manual Sap Error For Dead load Beam 153.17 KN.m 123.17 KN.m 19.8% Load Manual Sap Error For Dead load Column 580.23 KN.m 393.07 KN.m 32.25% 23 Design of Slab: Two-Way Ribbed Slab Beam Design: Column Design: Footing Design: F1 Tie Beam Design: Shear Wall Design: Stair Design: Mechanical Design Mechanical Design : 1- Water Supply . 2- Water Drainage 3- HVAC System . Water supply system : Tanks: Individual demand in club building from water is 50 liter/person. The size of the tank will be computed over four days. 30% of the tank size is for firefighting and cleaning. Water consumption Water supply : In ground &first floor : meter : 3" vertical : 2" horizontal : 1.5" branch: 1” Water drainage: Total Fixture units for cafeteria (Ground floor) Total fixture units for Lecture hall - Ground floor Water drainage : Drainage system for educational zone Drainage system for cafeteria HVAC System : Theater Area :649 Cooling load :45.3 # of diffusers :34 Irrigate grass 38 Safety Design In Cafeteria Ground floor Fire system Sprinkler system Fire system Extinguisher system Emergency Exits Environmental Design Environmental Design: 1- The layers for the elements . 2- Thermal analysis . 3- Daylight factor . 4- shading design 5- Acoustical design . External Wall Material U-Value:0.8108 (W/m2.K) Partition Material U-Value:1.4733 (W/m2.K) Roof Wall Material U-Value:1.275(W/m2.K) Floor Material U-Value:2.9582 (W/m2.K) Peak cooling = 429.162 KW. Peak heating = 61.926 KW. Women Recreation Center Double Tented Glass: U-Value = 2.4 Solar Heat transmitted = 15% Visible Light Transmitted =35% Environmental Design 52 5/19/2016 Women Recreation Center Average Daylight Values zone Floor Orientation DF-Value Picture Cafetria Ground floor North-west 5.85% lecture hall one Ground floor East 5.99% Concerns one Ground floor East 3.23% Concerns two Ground floor East 2.97% 53 lecture hall one Ground floor East 4.76% kidzania 1st Floor North-west 5.53% library 1st Floor South 2.19% Office one 1st Floor East 3.18% Office two 1st Floor East 2.49% Shading Design the concept of vertical louvers in the east and west elevation the concept of horizontal cantilevers in the south elevation 55 Acoustical Design RT60 Values for Museum in F.F floor before modifications Museum volume = 1985.77 m3 Occupancy: 133 RT60 Empty Case RT60 Full case As it's shown in the standards, the reverberant time inside the Dining room does not match the specifications of restaurants that is ( 0.8 – 1.2 ) s 57 Acoustic panels. Used decorative sound absorption materials. RT60 Values for Musuem in F.F floor before modifications RT60 Values for Musuem in FF floor after modifications All values lies in the range (0.8-1.2) Which is suitable for Dining rooms. 59 STC Calculations For external walls Required STC > 50 56 Impact Insulation Class : STC and IIC for celling Electrical Design Artificial lighting : The simulation analysis and design by “DIALux” Function Recommended Lux Targeted Lux (avg.) Uo Reflection Factor Ceiling Wall Floor Theater 300 382 0.455 70 82 30 Computer room 500 515 0.61 73 29 30 Lecture Room 500 530 0.674 70 75 30 Concerns 500 631 0.611 70 82 30 Kitchen 500 522 0.816 70 40 30 Library 500 619 0.624 70 82 30 Reception 300 317 0.663 70 50 20 multipurpose hall 300 423 0.487 70 82 30 Library 500 619 0.624 70 82 30 museum 200 Office library 500 705 0.606 70 82 30 Office staff 500 657 0.617 70 82 30 Office director 500 656 0.643 70 82 30 Conference room 500 735 0.722 70 82 30 Dialux program were used in our analysis to get a helpful and useful allocation of the artificial lighting, two different spaces were chosen to test and those were, manager ,dinning, kitchen, employee area and storage. a targeted value of U (uniformity) and (unified glare rating) UGR shall be achieved for each space where U >0.6 and UGR should not exceed 19, so to get these values suitable paint, tile, color of furniture and appropriate type of lamp have to be applied.[25] 63 Artificial lighting for computer room Indoor Luminaire with Louver Mounted Batten Commercial Indoor Luminaire with reflector Artificial lighting for Theater lighting Colored and moving head LAMP 9242660 KONIC OPAL Quantity surveying and cost estimation Quantity surveying and cost estimation: The total cost of the Culture design is about 14.76 million NIS The total cost per meter square for the culture center is about 477 Denar/m². image1.jpeg image2.png image3.jpeg image4.png image5.png image6.jpeg image7.jpeg image8.jpeg image9.jpeg image10.png image11.jpeg image12.jpeg image13.jpeg image14.png image15.png image16.png image17.png image18.png image19.png image20.png image21.png image22.png image23.png image24.png image25.png image26.png image27.png image28.png image29.png image30.png image31.png image32.png image33.png image34.png image35.png image36.png image37.png image38.png image39.png image40.png image41.png image42.png image43.png image44.png image45.jpeg image46.png image47.png image48.png image49.png image50.png image51.png image52.png image53.jpeg image54.jpeg image55.jpeg image56.jpeg image57.jpeg image58.jpeg image59.jpeg image60.jpeg image61.jpeg image62.png image63.jpeg image64.png image65.png image66.png image67.png image68.png image69.jpeg image70.jpeg image71.png image72.png image73.png image74.png image75.png image76.png image77.png image78.png image79.png image80.png image81.jpeg /docProps/thumbnail.jpeg